Automatic Heater
Clears window from ice
-
Base Mounting
TBA
-
Detector Type
Focal Plane Array (FPA), uncooled microbolometer
-
Focal Length
4 mm
-
Housing Material
Aluminium
-
IR Resolution
320 × 240 pixels
-
Packaging Size
534mm x 207mm x 230mm
-
Size
460mm × 140mm × 159mm
-
Spectral Range
7.5–13 µm
-
Weight
11 lbs
-
Digital I/O Connector Type
6-pole Jackable Screw Terminal
-
Digital I/O Isolation Voltage
500 VRMS
-
Digital I/O Supply Voltage
12–24 VDC, max. 200 mA
-
Digital input purpose
Image tag (start/stop/general), Input ext. device (programmatically read)
-
Digital Inputs
2 opto-isolated, 10–30 VDC
-
Digital Output Purpose
Output to ext. device (programmatically set)
-
Digital Outputs
2 opto-isolated, 10–30 VDC, max 100 mA
-
Ethernet
Control and image
-
Ethernet Communication
TCP/IP socket-based FLIR proprietary
-
Ethernet Connector Type
RJ-45
-
Ethernet Image Streaming
16-bit 320 × 240 pixels @ 60 Hz - Signal linear - Temperature linear - Radiometric GigE Vision and GenICam compatible
-
Ethernet Protocols
TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP
-
Ethernet Standard
IEEE 802.3
-
Ethernet Type
Gigabit Ethernet
-
Ethernet Video Streaming
MPEG-4, ISO/IEC 14496-1 MPEG-4 ASP@L5
-
Atmospheric Transmission Correction
Automatic, based on inputs for distance, atmospheric temperature and relative humidity
-
Bump
5 g, 11 ms (IEC 60068-2-27)
-
EMC
EN 61000-6-2 (Immunity), EN 61000-6-3 (Emission), FCC 47 CFR Part 15 Class B (Emission)
-
Emissivity Correction
Variable from 0.01 to 1.0
-
Encapsulation
IP 66 (IEC 60529)
-
Humidity
IEC 60068-2-30/24 h 95% relative humidity +25°C to +40°C
-
Storage Temperature Range
–40°C to +70°C
-
Operating Temperature Range
–25°C to +50°C
-
Vibration
2 g (IEC 60068-2-6)
-
Detector Pitch
25 µm
-
Detector Time Constant
Typical 12 ms
-
f-number
1.3
-
FOV
90° × 73°
-
Focus
Automatic or Manual
-
Image Frequency
30 Hz
-
Lens Identification
Automatic
-
Minimum Focus Distance
20mm
-
Spatial resolution
6.3 mrad
-
Accuracy
±4°C (±7.2°F) or ±4% of reading
-
Area
10 boxes with max./min./average/position (7 if FLIR Sensors Manager is used)
-
External Optics & Windows Correction
Automatic, based on input of optics/window transmission and temperature
-
Measurement Corrections
Global object parameters
-
Object Temperature Range
–20 to +120°C (–4 to +248°F) 0 to +350°C (+32 to +662°F)
-
Thermal Sensitivity/NETD
< 0.05°C @ +30°C (+86°F) / 50 mK
-
External Power Connector Type
2-pole jackable screw terminal
-
Heater External Power Connector Type
2-pole jackable screw terminal
-
External Power Operation
The camera operates on 12/24 VDC, 9 W max. (allowed range: 10-30 VDC) and heaters on 24 VDC, 25 W max. In total: 34 W.
-
Heater External Power Operation
24 VDC, 25 W max.
-
Voltage
Allowed range 10–30 VDC
-
Heater Voltage
Allowed range 21-30 VDC