Automatic Heater
Clears window from ice
Base Mounting
TBA
Detector Type
Focal Plane Array (FPA), uncooled microbolometer
Focal Length
18 mm
Housing Material
Aluminium
IR Resolution
320 × 240 pixels
Packaging Size
534mm x 207mm x 230mm
Size
460mm × 140mm × 159mm
Spectral Range
7.5–13 µm
Weight
11 lbs
Digital I/O Connector Type
6-pole Jackable Screw Terminal
Digital I/O Isolation Voltage
500 VRMS
Digital I/O Supply Voltage
12–24 VDC, max. 200 mA
Digital input purpose
Image tag (start/stop/general), Input ext. device (programmatically read)
Digital Inputs
2 opto-isolated, 10–30 VDC
Digital Output Purpose
Output to ext. device (programmatically set)
Digital Outputs
2 opto-isolated, 10–30 VDC, max 100 mA
Ethernet
Control and image
Ethernet Communication
TCP/IP socket-based FLIR proprietary
Ethernet Connector Type
RJ-45
Ethernet Image Streaming
16-bit 320 × 240 pixels @ 60 Hz - Signal linear - Temperature linear - Radiometric GigE Vision and GenICam compatible
Ethernet Protocols
TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP
Ethernet Standard
IEEE 802.3
Ethernet Type
Gigabit Ethernet
Ethernet Video Streaming
MPEG-4, ISO/IEC 14496-1 MPEG-4 ASP@L5
Atmospheric Transmission Correction
Automatic, based on inputs for distance, atmospheric temperature and relative humidity
Bump
5 g, 11 ms (IEC 60068-2-27)
EMC
EN 61000-6-2 (Immunity), EN 61000-6-3 (Emission), FCC 47 CFR Part 15 Class B (Emission)
Emissivity Correction
Variable from 0.01 to 1.0
Encapsulation
IP 66 (IEC 60529)
Humidity
IEC 60068-2-30/24 h 95% relative humidity +25°C to +40°C
Storage Temperature Range
–40°C to +70°C
Operating Temperature Range
–25°C to +50°C
Vibration
2 g (IEC 60068-2-6)
Detector Pitch
25 µm
Detector Time Constant
Typical 12 ms
f-number
1.3
FOV
25° × 18.8°
Focus
Automatic or Manual
Image Frequency
30 Hz
Lens Identification
Automatic
Minimum Focus Distance
0.4m
Spatial resolution
1.36 mrad
Accuracy
±4°C (±7.2°F) or ±4% of reading
Area
10 boxes with max./min./average/position (7 if FLIR Sensors Manager is used)
External Optics & Windows Correction
Automatic, based on input of optics/window transmission and temperature
Measurement Corrections
Global object parameters
Object Temperature Range
–20 to +120°C (–4 to +248°F) 0 to +350°C (+32 to +662°F)
Thermal Sensitivity/NETD
< 0.05°C @ +30°C (+86°F) / 50 mK
External Power Connector Type
2-pole jackable screw terminal
Heater External Power Connector Type
2-pole jackable screw terminal
External Power Operation
The camera operates on 12/24 VDC, 9 W max. (allowed range: 10-30 VDC) and heaters on 24 VDC, 25 W max. In total: 34 W.
Heater External Power Operation
24 VDC, 25 W max.
Voltage
Allowed range 10–30 VDC
Heater Voltage
Allowed range 21-30 VDC