Alarm Functions
6 automatic alarms on any selected measurement function, Digital In, Camera temperature, timer
Alarm Output
Digital Out, log, store image, file sending (ftp), email (SMTP), notification
Automatic Heater
Clears window from ice
Base Mounting
TBA
Detector Type
Focal Plane Array (FPA), uncooled microbolometer
Difference Temperature
Delta temperature between measurement functions or reference temperature
Focal Length
30.38 mm
Housing Material
Aluminium
IR Resolution
320 × 240 pixels
Contents
Cardboard box, Infrared camera with lens and environmental, housing, FLIR Sensors Manager download card, FLIR Tools & Utilities CD-ROM, Lens cap, Printed documentation, Small accessories kit, User documentation CD-ROM
Packaging Size
534mm x 207mm x 230mm
Set-up Commands
Date/time, Temperature°C/°F
Size
460mm × 140mm × 159mm
Spectral Range
7.5–13 µm
Weight
11 lbs
Zoom
1–8× continuous, digital, interpolating zooming on images
Digital I/O Connector Type
6-pole Jackable Screw Terminal
Digital I/O Isolation Voltage
500 VRMS
Digital I/O Supply Voltage
12–24 VDC, max. 200 mA
Digital input purpose
Image tag (start/stop/general), Input ext. device (programmatically read)
Digital Inputs
2 opto-isolated, 10–30 VDC
Digital Output Purpose
As function of ALARM, Output to ext. device (programmatically set)
Digital Outputs
2 opto-isolated, 10–30 VDC, max 100 mA
Ethernet
Control, result and image
Ethernet Communication
TCP/IP socket-based FLIR proprietary
Ethernet Connector Type
RJ-45
Ethernet Image Streaming
16-bit 320 × 240 pixels @ 7-8 Hz- Radiometric
Ethernet Power
Power over Ethernet, PoE IEEE 802.3af class 0
Ethernet Protocols
Ethernet/IP, Modbus TCP, TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP
Ethernet Standard
IEEE 802.3
Ethernet Type
100 Mbps
Ethernet Video Streaming
MPEG-4, ISO/IEC 14496-1 MPEG-4 ASP@L5
Storage Media
Built-in memory for image storage
Video Out
Composite video output, PAL and NTSC compatible
Video Connector Type
Standard BNC connector
Atmospheric Transmission Correction
Automatic, based on inputs for distance, atmospheric temperature and relative humidity
Bump
5 g, 11 ms (IEC 60068-2-27)
EMC
EN 61000-6-2 (Immunity), EN 61000-6-3 (Emission), FCC 47 CFR Part 15 Class B (Emission)
Emissivity Correction
Variable from 0.01 to 1.0
Encapsulation
IP 66 (IEC 60529)
Humidity
IEC 60068-2-30/24 h 95% relative humidity +25°C to +40°C
Storage Temperature Range
–40°C to +70°C
Operating Temperature Range
–25°C to +50°C
Vibration
2 g (IEC 60068-2-6)
Color Palettes
Color palettes (BW, BW inv, Iron, Rain)
Detector Pitch
25 µm
Detector Time Constant
Typical 12 ms
f-number
1.3
FOV
25° × 18.8°
Focus
Automatic or Manual
Image Frequency
30 Hz
Lens Identification
Automatic
Minimum Focus Distance
1.2m
Spatial resolution
1.36 mrad
Video Standard
CVBS (ITU-R-BT.470 PAL/SMPTE 170M NTSC)
Accuracy
±4°C (±7.2°F) or ±4% of reading
Area
10 boxes with max./min./average/position (7 if FLIR Sensors Manager is used)
External Optics & Windows Correction
Automatic, based on input of optics/window transmission and temperature
Isotherm
1 with above/below/interval
Measurement Corrections
Global and individual object parameters
Object Temperature Range
–20 to +120°C (–4 to +248°F) 0 to +350°C (+32 to +662°F)
Optics Transmission Correction
Automatic, based on signals from internal sensors
Reference Temperature
Manually set or captured from any measurement function
Reflected Apparent Temperature Correction
Automatic, based on input of reflected temperature
Spot Meter
10
Thermal Sensitivity/NETD
< 0.05°C @ +30°C (+86°F) / 50 mK
External Power Connector Type
2-pole jackable screw terminal
Heater External Power Connector Type
2-pole jackable screw terminal
External Power Operation
The camera operates on 12/24 VDC, 9 W max. (allowed range: 10-30 VDC) and heaters on 24 VDC, 25 W max. In total: 34 W.
Heater External Power Operation
24 VDC, 25 W max.
Voltage
Allowed range 10–30 VDC
Heater Voltage
Allowed range 21-30 VDC
File Formats
Standard JPEG, 16-bit measurement data included