Alarm Functions
On any selected measurement function, digital in, internal camera temperature
-
Alarm Output
Digital out, email (SMTP) (push), EtherNet/IP (pull), file transfer (FTP) (push), Modbus TCP master write (push), Modbus TCP slave (pull), MQTT (push), Query over RESTful API (pull), store image or video
-
Base Mounting
4× M4 on 4 sides
-
Field of view (FOV)
24° × 18°
-
Focal Length
17 mm (0.67 in)
-
Housing Material
Aluminium
-
IR Resolution
464 × 348 pixels
-
Object Temperature Range
15°C to 45°C (59°F to 113°F); camera provides contrast from -20°C to 120°C (-4°F to 248°F) but will not provide temperature information
-
Packaging Size
123mm × 77mm × 77 mm
-
Web Interface
Yes
-
Weight
0.82 kg (1.8 lb), camera only
-
Contrast Enhancement
FSX / Histogram equalization (IR only)
-
Multi-Streaming
Yes
-
FLIR Screen-EST Mode
Yes
-
Accuracy [Drift] in Screen-EST Mode
±0.3°C (±0.5°F)
-
Digital I/O connector type
M12 12-pin A-coded, Male (shared with external power)
-
Digital I/O isolation voltage
500 VRMS
-
Digital input purpose
NUC, NUC disable, alarm, update screening reference sample
-
Digital Inputs
2x opto-isolated, Vin(low)= 0–1.5 V, Vin(high)= 3–25 V
-
Digital Output Purpose
As a function of alarm, output to external device (e.g. when screening alarm is triggered); fault (NC)
-
Digital Outputs
3x opto-isolated, 0–48 V DC, max. 350 mA; solid-state opto relay; 1x dedicated as Fault output (NC)
-
Ethernet
For control, result, image, and power
-
Ethernet Communication
TCP/IP socket-based FLIR proprietary
-
Ethernet Connector Type
M12 8-pin X-coded, female; RP-SMA, female
-
Ethernet Power
Power over Ethernet, PoE IEEE 802.3af class 3
-
Ethernet Protocols
EtherNet/IP, IEEE 1588, Modbus TCP Master, Modbus TCP Slave, MQTT, SNMP; TCP, UDP, SNTP, RTSP, RTP, HTTP, HTTPS, ICMP, IGMP, sftp (server), FTP (client), SMTP, DHCP, MDNS (Bonjour), uPnP
-
Ethernet Standard
IEEE 802.3
-
Ethernet Type
1000 Mbps
-
RS-232
N/A
-
WiFi
Yes. RP-SMA, female connector
-
Ethernet Interface
Wired, Wi-Fi
-
Multicast
Yes
-
Unitcast
Yes
-
Atmospheric Transmission Correction
Based on inputs of distance, atmospheric temperature, and relative humidity
-
EMC
ETSI EN 301 489-1 (radio), ETSI EN 301 489-17 (radio), EN 61000-4-8 (magnetic field), FCC 47 CFR Part 15 Class B (emission US), ISO 13766-1 (EMC - Earth-moving and building construction machinery), EN ISO 14982 (EMC - Agricultural and forestry machinery)
-
Emissivity Correction
Variable from 0.01 to 1.0
-
Encapsulation
IEC 60529, IP 54, IP66 with accessory
-
Humidity (Operating and Storage)
IEC 60068-2-30/24 hours, 95% relative humidity, 25°C–40°C (77°F–104°F)/2 cycles
-
Operating Temperature Range
-20°C to 50°C (-4°F to 122°F); cooling plate needed for temperatures above 40°C (104°F)
-
Radio Spectrum
FCC 47 CFR Part 15 Class C (2.4 GHz band US) • FCC 47 CFR Part 15 Class E (5 GHz band US) • RSS-247 (2.4 GHz and 5 GHz band Canada) • ETSI EN 300 328 V2.1.1 (2.4 GHz band EU) • ETSI EN 301 893 V2.1.1 (5 GHz band EU)
-
Shock
IEC 60068-2-27, 25 g
-
Tripod Mounting
UNC ¼″-20 on 2 sides
-
Vibration
IEC 60068-2-6, 0.15 mm at 10–58 Hz and 2 g at 58–500 Hz, sinusoidal • IEC 61373 Cat 1 (Railway)
-
Lens Transmission Correction
Automatic, based on signals from internal sensors
-
Measurement Frequency
Up to 10 Hz
-
Schedule Response
sftp (image), SMTP (image and/or measurement data/result)
-
Video Storage
Up to 10 H.264 videos stored as a function of alarm; 5 sec before or after alarm
-
Camera f-number
1.3
-
Detector Type & Pitch
Uncooled microbolometer, 17µm
-
Focus
One-shot contrast, motorized, and manual
-
Image Frequency
30 Hz
-
Lens
24°
-
Lens Identification
Automatic
-
Radiometric IR video streaming
RTSP protocol
-
Readout
For measurement results: EtherNet/IP (pull); Modbus TCP master (push); Modbus TCP slave (pull); MQTT (push); Query over REST API (pull): measurements and still image (radiometric JPEG, visual 640 × 480, visual 1280 × 960) read access only; web interface
-
Spatial resolution (IFOV)
0.90 mrad/pixel
-
Spectral Range
7.5–14 µm
-
Streaming Resolution
RTSP video streaming (source 0) - 640 × 480 pixels; RTSP video streaming (source 1) - 1280 × 960; radiometric streaming: 640 × 480 pixels
-
Video Streaming
RTSP protocol
-
Overlay
With / Without
-
Visible Camera
Included
-
External Optics & Windows Correction
Based on input of optics/window transmission and temperature
-
Measurement Corrections
Global object parameters, local parameters per analyze function, external blackbody correction
-
Measurement Presets
Yes
-
Reflected apparent temperature correction
Based on input of reflected temperature
-
Automatic Hot/Cold Detection
Max/min temperature value and position shown within box
-
Thermal Sensitivity_NETD [typical]
<40 mK @ 30°C (86°F)
-
External Power Operation
24/48 V DC 8 W max
-
Power Connection
M12 12-pin A-coded, male (shared with Digital I/O)
-
Power Consumption
7.5 W at 24 V DC typical • 7.8 W at 48 V DC typical • 8.1 W at 48 V PoE typical
-
External Voltage
Allowed range 18–56 V DC
-
Image Source
Visual / IR / MSX